The application that the stage amounts to control of transducer moment of force to go up in embossing machine of aluminum foil paper (go up)
- Time:
- Click:122
Moment of force of standards of 1 electric machinery puts an electric machinery: ABBQABP160M6A380V/17.
Constant power of 50-100 of 9A/5-50HZ constant torsion / 7.
5kw, 380VAC of electric machinery fan, electric machinery axis carries coder + 12V/A/B/512ppr. Press beautiful electric machinery: Qu Fu gold rises electric machinery 380V/11.
5A/50HZ/5.
5KW/4 extremely / constant power of 50-100 of 5-50HZ constant torsion, moment of force of 380VAC of electric machinery fan receives an electric machinery: ABBQABP132M4A380V/7.
5KW/15.
Constant power of 50-100 of 8A/50HZ/5-50HZ constant torsion, 380VAC of electric machinery fan, electric machinery axis carries coder + 12V/A/B/512ppr. 3.
Drive of 2 torsion that amount to constant controls a system to configure a stage to amount to feeling screen DOPA58CSTD; PLC stage amounts to DVP16ES00R (form a complete set is patulous 4DA/4AD module) ; Put a transducer VFD075V43A-2 (780W/75ohm of resistor of apply the brake of form a complete set) ; Receive a transducer VFD075V43A-2 (780W/75ohm of resistor of apply the brake of form a complete set) ; VFD055V43A-2 of the transducer that press a flower (520W/100ohm of resistor of apply the brake of form a complete set) . 3.
3 electric principles design electric principle to refer to a graph 3: Electric hookup. Graph moment of force of transducer of series of 4VE of 3 electric hookup controls parameter 4.
The setting process of 1 transducer parameter (1) the parameter setting that receives a transducer takes transducer empty electric machinery to make VF move, and observe condition of electric accident travel (output voltage / output electric current / actual rotate speed) : Pr.
NoMODBUSDescriptionUnitData01-010101HMotor1FbaseHz50.
0001-020102HMaxOut-Volt1V380.
010-000A00HEncoderpulses51210-010A01HPGinputsetting1 dictates transducer to frequency installs 50hz, look carefully at R condition to be + 1490rpm. Write electric machinery parameter transducer correspondence parameter: Pr.
NoMODBUSDescriptionUnitData05-010501HMotor1RatedAAmps15.
8005-020502HMotro1RatedPKw7.
5005-030503HMotor1RatedRPM149005-040504HMotor1Poles4 does electric machinery to be rectified oneself calm, and control means is changed control FOC+PG for vector, move it is normal to look; Electric machinery trends rectifies parameter of the electric machinery after deciding to express as follows: Pr.
NoMODBUSDescriptionUnitData05-050505HMotor1No-LoadAmps6.
7505-060506HMotor1Rsohm1.
16005-070507HMotor1Rrohm0.
96805-080508HMotor1LmmH186.
105-090509HMotor1LxmH18.
2 adjust control pattern and run from 0-50hz, it is normal to observe electric machinery condition (output voltage / output electric current / electric machinery rotate speed) Pr.
NoMODBUSDescriptionUnitData00-10000AHControlMethod3 controls means instead torsion to control TQR+PG, and adjust corresponding torsion parameter and outside terminal function: Pr.
NoMODBUSDescriptionUnitData00-10000AHControlMethod400-200014HSourceofFreq.
200-210015HSourceofOper.
101-000100HMaxOutputFreq.
Hz70.
0001-12010CH1stAccelTimesec8.
0001-13010DH1stDecelTimesec12.
0003-010301HACISelection203-12030CHACI/AVI2SEL107-210715HSOURCEOFTQR207-240718HSpeedLimitSel.
1 (2) the parameter setting that puts a transducer takes transducer empty electric machinery to make VF move, and observe condition of electric accident travel (output voltage / output electric current / actual rotate speed) : Pr.
NoMODBUSDescriptionUnitData01-010101HMotor1FbaseHz50.
0001-020102HMaxOut-Volt1V380.
010-000A00HEncoderpulses51210-010A01HPGinputsetting2 dictates transducer to frequency installs 50hz, look carefully at R condition to be + 995rpm. Write electric machinery parameter transducer correspondence parameter: Pr.
NoMODBUSDescriptionUnitData05-010501HMotor1RatedAAmps17.
9005-020502HMotro1RatedPKw7.
5005-030503HMotor1RatedRPM99505-040504HMotor1Poles6 does electric machinery to be rectified oneself calm, and control means is changed control FOC+PG for vector, move it is normal to look; Electric machinery trends rectifies parameter of the electric machinery after deciding to express as follows: Pr.
NoMODBUSDescriptionUnitData05-050505HMotor1No-LoadAmps11.
7405-060506HMotor1Rsohm1.
02705-070507HMotor1Rrohm0.
66905-080508HMotor1LmmH102.
505-090509HMotor1LxmH16.
2 adjust control pattern and run from 0-50hz, it is normal to observe electric machinery condition (output voltage / output electric current / electric machinery rotate speed) Pr.
NoMODBUSDescriptionUnitData00-10000AHControlMethod3 controls means instead torsion to control TQR+PG, and adjust corresponding torsion parameter and outside terminal function: Pr.
NoMODBUSDescriptionUnitData00-10000AHControlMethod400-200014HSourceofFreq.
200-210015HSourceofOper.
101-12010CH1stAccelTimesec12.
0001-13010DH1stDecelTimesec8.
0002-010201HMulti-FunInput13903-010301HACISelection203-12030CHACI/AVI2SEL107-210715HSOURCEOFTQR207-240718HSpeedLimitSel.
Direction of torsion of the 1 output when because put a transducer,working and rotate speed way are opposite, so setting of MI1 of will outside terminal is 39 functions torsion to command direction. CNC Milling